Ma PDU anzeru amapereka luso lapamwamba loyang'anira ndi kuyang'anira zomwe zimathandiza ogwiritsa ntchito kuwongolera mphamvu patali pazida zolumikizidwa, kuyang'anira momwe chilengedwe chikuyendera, ndikuwunika thanzi la magwero amagetsi a AC. Malo ochulukirapo a data amasankha PDU yanzeru kuti akweze kasamalidwe kawo pakugawa mphamvu. Muyenera kuganizira mfundo zotsatirazi musanapange chisankho:
1. Ganizirani zofuna zanu zamakono komanso zamtsogolo.
2. Unikani zida zanu za IT ndi zida zina zilizonse zolumikizidwa ndi PDU.
3. Kumvetsetsazinthu zofunikazomwe zimapanga PDU yanzeru yoyenera malo anu a data.
Kusintha: Imachita kutalikusintha kwa magetsi, kulola ogwira ntchito ku IT kuyatsa kapena kuzimitsa zida kuchokera pamalo apakati. Izi zitha kukhala zothandiza pakuwongolera kugwiritsa ntchito mphamvu ndikuchepetsa mtengo wamagetsi, komanso kuthetsa mavuto ndi kukonza ntchito. Ntchito yosinthira imatha kuwongoleredwa kudzera munjira zosiyanasiyana, monga mawonekedwe awebusayiti, mawonekedwe a mzere wamalamulo, kapena pulogalamu yam'manja. Ogwiritsa ntchito amatha kusankha malo ogulitsira kapena magulu omwe azitha kuyatsa kapena kuzimitsa. Ponseponse, ntchito yosinthira imapatsa ogwira ntchito ku IT kusinthasintha kwakukulu komanso kuwongolera kugawa kwamagetsi ku zida zawo, zomwe zimapangitsa kuti pakhale kasamalidwe koyenera komanso koyenera kazinthu zawo za data center.
Kuyeza: Izi zitha kukhala miyeso yamagetsi amtundu wonse wa PDU monga voteji, panopa, mbali ya gawo, mphamvu yamagetsi, ma frequency, ogwira ntchito, owonekera komanso ochitapo kanthu. Kuonjezera apo, n'zotheka kukonza malire a chiwerengero cha miyeso, yomwe, ngati yapitirira, imayambitsa alamu mwamsanga. Kuyeza uku kumatha kukhala pa PDU yonse kapena pagulu lililonse.
Newsunnma PDU anzerukukhala ndi zitsanzo za A, B, C, D malinga ndi ntchito.
Mtundu A: metering yonse + Kusintha kwathunthu + Kuyeza kwamunthu payekha + Kusintha kwapayekha
Mtundu B: Chiwerengero chonse cha mita + Kusintha kwathunthu
Mtundu C: Chiwerengero chonse cha metering + Payekha potulutsa mita
Mtundu D: Total metering
4. Dziwani mtundu wowongolera womwe mukufuna. Onani pansipa chithunzi cha gawo lowongolera la Newsunn'srack Mount wanzeru PDUs
Chiwonetsero cha LCD, doko la netiweki, doko la USB-B, doko la serial (RS485), doko la Temp/Chinyezi, doko la Senor, doko la I/O (kulowetsa/kutulutsa kwa digito)
5. Yerekezerani mphamvu zofunika ndi malire apano.
6. Ganizirani zina zowonjezera monga chitetezo cha mawondo ndi mphamvu zozindikira kutentha.
7. Ganizirani kukula kwa thupi ndi mawonekedwe a PDU, komanso kulemera kwake.
8. Fufuzani ntchito za wopanga ndi njira zothandizira.
9. Ganizirani mtengo wake ndipo mufunika kubweza zenizeni pazachuma chanu.
If you need a cost effective intelligent PDU, please contact Newsunn at sales1@newsunn.com.
Zikomo!